Overview
NX Multi-Mode Power Amplifiers are designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.
Available in three amplifier series, NX offers 2 or 4-channel models as NX (base model series), NXE (networkable), or NXP (networkable + DSP).
Features
All NX Models Include:
- Class-D Switching Amplifier Technology. NX features a universal switch-mode power supply with Power Factor Correction (PFC) that operates from 70VAC to 270VAC.
- Multi-Mode Operation. Selectable Outputs allow you to choose the desired output mode on each channel. Set the DIP-switch configuration for Low Impedance (2, 4, and 8 Ohm), or 25V, 70V, or 100V Constant Voltage and you’re set to go.
- Energy Efficiency. NX has power-saving Ashly EMS™ (Energy Management System) which provides an automatic sleep-mode drawing less than 1 Watt (defeatable).
- Ethernet Control using Protea™ NE software. Also, serial data control by Ashly programmable remotes or third party controllers, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional Dante™, CobraNet™, or AES3 digital audio capability (factory-installed).
- Real-Time Clock with Event Scheduler. Assign automatic execution of selected functions and tasks. The event scheduler is programmed from software and stored in the amplifier
- Ashly Remote Control via iPad® app. Use our free Ashly Remote app available for custom design of secure wireless control over network
- 32-bit SHARC DSP Processing at 48kHz or 96kHz Sample Rates. Comprehensive software control of digital signal processing, matrix and auto-mixing, built-in signal generator for test tone and noise-masking, swept output load impedance monitoring. Use Ashly Remote iPad control to select DSP functions including gain, mute, matrix, A/B source select, PEQ filter level, and meters.
- FIR Filter-Ready. Our PneS software will load a speaker manufacturer"s .fir or .csv file to achieve precision tuning.
nXp - Ethernet + DSP Series Additional Features
- Protea DSP including dynamics, gain, EQ, feedback suppression, FIR filters, matrix and auto-mixer, crossover, delay, and more
- Impedance monitoring of individual amplifier outputs for quick and easy diagnosis of potential speaker problems
- iPad control of select DSP functions including gain, mute, matrix, A/B source select, PEQ filter level, and meters
- Networkable remote gain and zone control using Ashly neWR-5 and FR-8/16
Specifications
Specifications Notes: 0dBu = 0.775 VRMS | ||
Voltage Gain | Selectable at 26dB, 32dB, 38dB, or 1.4V | |
Damping Factor | >250 (8 Ohm load <1kHz) | |
Input High Pass Filter | 80Hz 2nd order | |
Distortion (SMPTE, typical) | <0.5% | |
Distortion (THD-N, typical) | <0.5% (8 Ohms, 10dB below rated power, 20Hz–20kHz) | |
Channel Separation | -75dB (dB from full output, 1kHz) | |
Signal-to-Noise (unweighted) 20Hz-20kHz, Gain at 26dB | >99dB (all 150x models) >96dB (all 75x models) | |
Frequency Response | 20Hz-20kHz, +/-0.05dB | |
Balanced Input Connector | Euroblock 3.5mm | |
Input Impedance | 10k Ohms | |
Maximum Input Level | +21dBu | |
Speaker Output Connector | Euroblock 7.62mm | |
Control Network | RJ-45 connector, 100MB Ethernet | |
AUX Output Connector | Balanced Euroblock 3.5mm | |
AUX Output Maximum Level | +21dBu | |
Remote Standby Contact Closure | Euroblock 3.5mm, close contact pin to ground (G) for standby mode | |
Preset Recall Contact Closure | Euroblock 3.5mm, close contact to ground (G) for preset 1-4 recall | |
Data Connection | Euroblock 3.5mm – Gnd, +18V, Data Out, Data In | |
Fault Condition Logic Outputs | Euroblock 3.5mm – fault indicated by loss of 1Hz "heartbeat" pulse signal | |
Remote DC Level Control | Euroblock 3.5mm – Gnd, CV, V+ per input | |
Attenuators (per channel) | Rear panel, Fully off = Mute | |
Amplifier Protection | Shorted output power limiting, over-temperature, DC-output, power-supply fault, mains-fuses & inrush-current limiting | |
Cooling | Continuously variable temperature controlled fan | |
Environmental | 32°F-120°F, (0°C-49°C) non-condensing | |
Weights and Dimensions | ||
Unit Dimensions | 19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm) | |
Shipping Dimensions | 25.2"W x 2.5"H x 19.5"D (641mm x 64mm x 495mm) | |
Unit Weight | 1504/754 13.1lbs (5.9kg), 1502/752 12.1lbs (5.5kg) | |
Shipping Weight | 1504/754 16.0lbs (7.3kg), 1502/752 15.0lbs (6.8kg) | |
Front Panel LED Indicators | ||
POWER (white) | Switch: On, Off, Standby (flashing) | |
PROTECT (red) | On (fault condition or shut down), Of | |
SLEEP (blue) | On, amplifier is asleep from audio inactivity | |
DISABLE (yellow) | On, power switch & attenuators are disabled | |
COM (green) | On, for Ethernet data or Device ID | |
Per Channel | ||
CLIP/MUTE (red) | Clip at 1dB below rated output / Mute | |
SIGNAL (green) | -18dB below rated output | |
CURRENT (green) | Brightness is proportional to output current | |
TEMP(yelow) | On dim at 90% max operating temperature, On full bright + protect at 100% | |
BRIDGE (green) | Per Channel Pair, On, Of | |
Power Requirements (50 – 60Hz) | ||
Nominal Voltage Input | 100 – 240VAC | |
Operating Range | 70 – 270VAC | |
Minimum power-up | 70VAC | |
Power Supply Type | SMPS with active PFC (Power Factor Correction) | |
AC Mains Line Cord Connector | Detachable Nema 5-15 for USA (May vary for export) |