CONSTRUCTION & DIMENSIONS | |
CONDUCTOR PARAMETER | |
Number of Conductors | 1 |
AWG Size | 20 |
Conductor Stranding | Solid |
Conductor Type | Tinned Copper |
Nominal DCR | 10.1 Ohm/1000ft |
INSULATION PARAMETER | |
Insulation Type | Foam Polyethylene |
Insulation Thickness | 0.116 in |
SHIELDING PARAMETER | |
Shield Type | 100% Aluminum Foil95% Tinned Copper Braid |
ELECTRICAL CHARACTERISTICS | |
Nominal Impedance | 52 Ohm |
Nom. Cap. Between Conductors | 25 pF/ft |
OVERALL CONSTRUCTION PARAMETERS | |
Jacket Type | PVC |
Jacket Thickness | 0.031 in |
Nominal Cable O.D. | 0.195 in |
Plenum | No |
NEC UL Rating | CM |
RoHS Compliant | Yes |
Pull Tension | 45 lbs |
Bend Radius | 1.95 in |
Cable Weight | 30 lbs |
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS | |
Nominal Velocity of Propagation (VP) | 80 % |
Delay Skew | 1.54 ns/ft |
UL Flammability | UL1685 |
Operating Range | -40 to 75 Deg C |
UL Voltage Rating | 300 |
FREQUENCY (MHz) | ATTENUATION (db/100ft) |
1 MHz | 0.6 dB |
10 MHz | 1.5 dB |
50 MHz | 3.5 dB |
100 MHz | 4.7 dB |
200 MHz | 6.9 dB |
400 MHz | 10.2 dB |
900 MHz | 16.8 dB |
1000 MHz | 18.3 dB |