CONSTRUCTION & DIMENSIONS | - |
CONDUCTOR PARAMETER | - |
Number of Conductors | 6 |
AWG Size | 18 |
Conductor Stranding | 7x26 |
Conductor Type | Bare Copper |
Nominal DCR | 6.2 Ohm/1000ft |
INSULATION PARAMETER | - |
Insulation Type | PVC |
Insulation Thickness | 0.01 in |
Insulation Color Code | 1.Black,2.Red,3.White,4.Green,5. Brown,6.Blue |
SHIELDING PARAMETER | - |
Shield Type | Overall 100% Aluminum Foil |
Shield Type 2 | Aquaseal Water Blocking Tape |
Drain Wire Type | Tinned Copper |
Drain Wire AWG | 24 AWG |
ELECTRICAL CHARACTERISTICS | - |
Nom. Cap. Between Conductors | 68 pF/ft |
Nom. Cap. Conductor to Shield | 122 pF/ft |
OVERALL CONSTRUCTION PARAMETERS | - |
Jacket Type | UV Resistant PVC |
Jacket Thickness | 0.025 in |
Nominal Cable O.D. | 0.323 in |
Plenum | No |
NEC UL Rating | CM |
RoHS Compliant | Yes |
TIA Test | TIA455-82 Water Penetration Test |
Bend Radius | 2.907 in |
Cable Weight | 54 lbs |
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS | - |
UL Flammability | UL1685 |
Operating Range | -20 to 60 Deg C |
UL Voltage Rating | 300 |