Overview
External Control Plus. Designed for use with Radius, Prism, Edge, and Solus NX DSPs. Especially useful in conferencing and paging applications. Each of the 8 flexible analog control inputs may be configured for 1 potentiometer or 2 switches. The 16 logic outputs may be used to drive LEDs, trigger external relays, or control contact closure ports. Either of the 2 RS-232 ports may be configured to issue or receive commands to or from third-party control systems. Utilizing PoE, xControl may be mounted where convenient and connected to a control network using a single cable. The half-rack form factor conserves rack space, or if preferred, the xControl may be surface mounted at point-of-use.
Features
- Expanded External Control for Composer-enabled DSPs
- Analog / Logic Control Inputs | Logic Outputs | RS-232
- Flexible 1/2 Rack Form Factor
- Powered Via PoE (Switch or Injector)
Specifications
External Control Inputs
|
|
Number of External Control Inputs | 8 to 16 total; each configurable to accommodate 1 potentiometer or 2 closures for a maximum of 8 potentiometers or 16 closures. |
Connectors | 3.81 mm terminal blocks. |
Reference Voltage | 3.3 VDC |
Recommended Potentiometer | 10k Ohms linear taper. |
RS-232 Ports
|
|
Number of RS-232 Ports | 2 |
Connectors | 3.81 mm terminal blocks. |
RS-232 Port Parameter | 57.6 kbaud (default), 8 data bits, 1 stop bit, no parity, no flow control wired straight-through, only pins 2, 3, and 5 required. |
Mechanical Data
|
|
Space Required | Half rack unit (WDH: 20.83 cm x 22.86 cm x 4.37 cm / 8.2 in. x 9 in. x 1.72 in.) Depth does not include connector allowance. Allow at least 3 inches additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections. |
Electrical | PoE IEEE 802.3af Class 1, 6 Watts maximum. No line voltage switching required. |
Ventilation | Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in. minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc. |
Shipping Weight | 2.0 kg (4.4 lbs.) |
Certifications or Compliance | UL 60065, cUL 60065, IEC 60065, EN 55103-1, EN 55103-2, FCC Part 15, RoHS. |
Logic Outputs
|
|
Number of Logic Outputs | 16; each capable of driving an LED directly, triggering an external relay or sinking external voltage/current. Low (0 VDC) when active, pulled high (5 VDC) when inactive. |
Connectors | 3.81 mm terminal blocks. |
Maximum Output Voltage | 5 VDC |
Maximum Output Current | 10 mA |
Maximum External Power Supply Voltage | 24 VDC |
Maximum External Power Supply Current Sinking | 50 mA |
System
|
|
Ethernet Cable | Standard CAT5/6, maximum device-to-device length = 100 meters. |