Overview
The NEXSYS UPS Expandable Run Time Unit for the 2000VA NEXSYS UPS products give you that extra oomph when you need additional run time for your AV systems if/when a power anomaly occurs. Connect up to (4) Expandable Run Time Units for even more run time!
- Expandable Run Time Units can be daisy-chained from the NEXSYS UPS or plugged in directly.
- An Out-of-Box(y) Experience. Everything is assembled and connected right from the factory saving you time during your installations
- Rack ears are pre-installed with the “4-Post” mounting brackets ready to be rack mounted even if you have a 3rd pair of rackrail
- The battery is already connected so just plug it in.
- Pure Power. All NEXSYS UPS Expandable Run Time Units have a Pure Sine Wave output and AVR (automatic voltage regulation) providing the cleanest power to your connected equipment, especially the most sensitive equipment
- Swap it like it’s hot. Hot swappable battery from the front access panel for easy service without disrupting the system
- Available for the 2000VA NEXSYS UPS
- UPX-2000-2
- UPX-RLNK-2000-2
- UPX-RLNK-2000-8
• 8 outlets
- Bank Controlled option with (2) 4 outlet banks
- Individually Controlled options for all 8 outlets via RackLink™
• All NEXSYS UPSs have a Pure Sine Wave output and AVR
(automatic voltage regulation) providing the cleanest power
to your connected equipment, especially the most sensitive
equipment
• Everything is assembled and connected right from the factory
saving you time during your installations
- Rack ears are pre-installed with the “4-Post” mounting
brackets ready to be rack mounted even if you have a 3rd pair
of rackrail
- The battery is already connected so just plug it in
• The NEXSYS Power Management Software on your PC
allows you to customize and configure various settings and
notifications
• The NEXSYS UPSs are RackLink compatible for remote
monitoring and management and some are compatible right out
of the box! Look for RLNK in the part number. Use the RackLink
Discovery Tool on your on PC, Apple or Android devices and
connect directly to the UPS
• Set reminders or notifications for things like battery
replacement, etc. via email or on the UPS
• Front panel LCD screen shows UPS Device Name, Model
Number, Serial Number
• Hot swappable battery from the front access panel for easy
service without disrupting the system
• The IEC Input allows for better cable management of the power
cord if shorter or longer cords are required
- All UPSs include a 6’ (1.8m) IEC power cord
• Energy Star Certified
• U.S. Department of Energy Compliant for energy efficiency
Rackmount Uninterruptible Power Supply (UPS) shall be Middle Atlantic Products model # UPX- __ R-2 or UPX-
RLNK-__-__ (refer to chart). UPS shall be line interactive with AVR. Unit shall measure 19.00” W x 3.50” H x __.00”
D (refer to chart for depth) and occupy 2 rack spaces. UPS shall have a rear mounting range of 20” to 36”. UPS shall
have slim rail mounting allowing mounting with a pair of middle rack rail. Unit shall operate on 120 VAC/60Hz current
with a Power Factor of 0.9. Unit shall have a nominal output of 120V with optional selection for 110V or 127V. Unit shall
have a capacity of __ VA and __ W (refer to chart). Unit shall have (8) NEMA 5- __ receptacles on the rear of the unit
(refer to chart). Unit shall have all outlets controlled via 2 banks for selection of non-critical load shedding, or individual
outlet control, depending on model. Unit shall be IP enabled, depending on model (RLNK models), or when used with
optional RackLink™ Network card, model# UPX-RLNK-CARD. Rackmount UPS shall include an IEC-C13 detachable 6’
(1.83m) SignalSAFE™ power cord with NEMA __ (refer to chart) plug. UPS shall have all mode surge suppression and
overload protection. Rackmount UPS shall have a hot swappable battery that allows for a __ minute run time at half
load and a __ (refer to chart) minute run time at full load. Rear of unit shall have inputs that allow for the installation of
up to 4 additional hot swappable batteries. Rackmount UPS shall utilize Middle Atlantic NEXSYS Power Management
software. Rackmount UPS shall be warrantied to be free from defects in materials and workmanship under normal
use and conditions for a period of 3 years; battery shall be warrantied for a period of 2 years. Rackmount UPS shall be
tested to UL 1778 and CAN CSA-C22.2 standards in US and Canada. Rackmount UPS shall be FCC Class A certified
and complies with Canadian ICES-003. Rackmount UPS shall be EnergyStar 2.0 certified.
Expandable Battery Pack
Rackmount expandable run time battery pack shall be Middle Atlantic Products model# UPX-EXPANRUN-__-__ (refer
to char). UPX-EXPANRUN-10-15 shall be suitable for use with UPX-1_00R-2 and UPX-RLNK-1_00R-_ (refer to chart).
UPX-EXPANRUN-20 shall be suitable for use with UPX-2000R-2 and UPX-RLNK-2000R-_UPS-2200R. UPS-EBPR shall
measure 19.00” W x 3.50” H x __” D (refer to chart for depth) and occupy 2 rack spaces. UPS-EBPR shall require __”
useable depth (refer to chart). With __ hot swappable batteries connected to the unit, there is a __ minute run time at
half load and a __ minute run time at full load (refer to chart). Rackmount expandable run time battery pack shall be
warrantied to be free from defects in materials and workmanship under normal use and conditions for a period of 3 years;
battery shall be warrantied for a period of 2 years. Rackmount expandable run time battery pack shall be tested to UL
1778 and CAN CSA-C22.2 standards for US and Canada. Rackmount UPS shall be FCC Class A certified and complies
with Canadian ICES-003.