Kramer BCLS-11GY-3

Kramer BCLS-11GY-3

Kramer BCLS-11GY-3

Kramer BCLS-11GY-3

CAT 5E U/UTP LSZH Bulk Cable-305m

SKU: KRMR-99-45100305
MSRP: $178.00
MAP: $142.40

Overview

Kramer's BCLS−11 is a high−performance CAT 5E U/UTP cable designed for IT, LAN and Ethernet installations. BCLS−11 is constructed with four pairs of 24AWG solid bare copper conductors in an LSZH jacket with internal rip cord and sequential markings every meter. It is packed in a Reelex II carton for easy to pull−out. BCLS−11 exceeds CAT 5E specifications to provide additional performance and bandwidth beyond the basic standard.

Features

  • High–Performance Transmission.
  • High–Quality Safety Properties.
  • Sweep Frequency up to 350 MHz.
  • Length — Available in Reelex II Cartons of 305m (1000ft).

Specifications

CONSTRUCTION

  • Conductor: 4 pairs of 24AWG solid bare copper
  • Insulation: Polyolefin (PO), blue & white/blue stripe, orange & white/orange stripe, green & white/green stripe, brown & white/brown stripe
  • Twist: Conductors: left–hand, assembly: left–hand
  • Rip Cord: Polyester multi–yarn
  • Jacket: Low smoke zero halogen (LSZH), gray (Pantone 427C)

DIAMETERS

  • Jacket: Diameter: 4.9 ±0.2mm, thickness: 0.50 ±0.05mm
  • Conductors: 0.87mm (0.034") ±0.02mm (0.001")

ELECTRICAL

  • Temperature & Voltage Rating: 60°C @300V
  • Spark Test: 2.5kV DC
  • AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket
  • Coupling Attenuation: ≤55dB @30MHz, ≤55dB @100MHz
  • Conductor DC Resistance: ≤9.38Ω /100m
  • Resistance Unbalance: ≤5%
  • Dielectric Strength: 1.5kV AC for 2sec
  • Insulation Resistance: ≥5000MΩ /m
  • Mutual Capacitance: ≤5.6nF /100m
  • Capacitance Unbalance: ≤330pF /100m pair–to–ground
  • Characteristic Impedance: 100±15Ω @1~100MHz
  • Coupling Attenuation: ≤55dB @30MHz, ≤55dB @100MHz

USAGE AND ENVIRONMENTAL

  • Cable Cold Bend: –20°C for 4hr
  • Insulation Tensile Strength: 2400 PSI min. (1.69kg/m^2)
  • NVP: 71%
  • Temperature Range: Storage & shipping: — 20°C to 60°C, installation: — 0°C to 60°C, operation: — 20°C to 60°C
  • Minimum Bending Radius: ≥4 times of overall diameter
  • Maximum Pulling Tension: ≤110N

REGULATORY PERFORMANCE

  • ANSI/TIA-568-C.2 (2009): Balanced Twisted–Pair Telecommunications Cabling and Components Standards
  • ISO/IEC 11801 (Edition 2.2): Information technology — Generic cabling for customer premises
  • IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications — Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz — Horizontal floor wiring — Sectional specification
  • EN 50288-3-1 2013: Multi–element metallic cables used in analogue and digital communication and control sectional specification for unscreened cables characterized up to 100 MHz. horizontal and building backbone cables

REGULATORY SAFETY

  • EN 50173-1 2011: Information technology — Generic cabling systems — Part 1: General requirements
  • IEC 60332-1-2: Tests on electric and optical fibre cables under fire conditions — Part 1–2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1 kW pre–mixed flame
  • IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
  • IEC 60754-2: Test on gases evolved during combustion of materials from cables