Overview
Sensor3 power control systems provide high-density, professional features and exceptional reliability for lighting applications requiring top-of-the-line power control.
APPLICATIONS
- Professional and academic theatres
- Production studios
- Concert and performance halls
- Theme parks
- Themed retail and dining venues
- Hotels
- Multipurpose convention centers
- Arenas and stadiums
- Houses of worship
Features
- Rugged industrial construction
- 100,000 A Short Circuit Current Rating (SCCR)
- Standard system monitoring with optional Advanced Features (AF) per-circuit reporting
- Adaptable modular design
- Up to 96 power control channels per enclosure
- Two 2.4 kW circuits or two 1 kW electronic low voltage circuits per module
- 6-, 12-, 24-, and 48- module enclosures available
- Direct Ethernet control-signal input (Net3, sACN)
- Advanced configuration editing over network
- Two DMX512-A inputs
Specifications
GENERAL
- Enclosures available in four sizes:
- 6 modules, 12 circuits maximum
- 12 modules, 24 circuits maximum
- 24 modules, 48 circuits maximum
- 48 modules, 96 circuits maximum
- Dual-density modules (two circuits per module)
- Operating temperature: 0°–40°C (32°–104°F)
- Electrical room HVAC systems must maintain the specified ambient temperature at the enclosure at all times.
- Relative humidity: 10–90% non-condensing
MECHANICAL
- Rugged 16-gauge steel construction
- Fine-textured, scratch-resistant epoxy paint
- Top and bottom conduit access through removable panels (SR3-48) or knockouts (SR3-6, SR3-12, and SR3-24)
- Keyed module slots prevent insertion of incompatible module types
- Front access to all wiring and terminations
- Full-height locking door
- Electrostatic air filter easily removed from door for periodic cleaning
- High-efficiency cooling system with reporting
- High-visibility LED status beacon
ELECTRICAL
- SR3 enclosures accept the following feeds:
- Three-phase 120 / 208 VAC
- Single-phase 120 / 240 VAC
- SR3N enclosures accept the following feeds:
- Three-phase 100 / 170 VAC
- Line feed frequencies from 47–63 Hz
- Line feed voltage range is 91–139 VAC
- Max main transformer tap recommended is 135 V to allow for line fluctuation
- Short Circuit Current Rating: 100,000 A RMS symmetrical
CONTROL ELECTRONICS
- CEM3 Power Control Processor
- UL 924 Listed panic input for emergency lighting control
- Full number pad for fast access to dimmer override and setup
- Supports Dimmer Doubling
- System, enclosure, and diagnostic reporting standard
- Per-circuit reporting available with AF enclosures and modules
- CONTROL POWER BACKUP OPTIONS
- RideThru Option (RTO):
- Seamless transfer to backup power upon loss of incoming line power
- Provides backup power for at least 6 seconds during power loss
- Automatically recharges from power feed
- Battery Pack Option (BP, BP2):
- Seamless transfer to battery power upon loss of normal power
- Provides backup power for 30 minutes during normal power loss
- Automatically recharges from power feed during normal power conditions
- Two hour recharge time from full discharge
REGULATORY AND COMPLIANCE
- All enclosures are cULus Listed