No more wasting resources lighting an empty room. Buildings can waste electricity as a result of lights being left on in an unoccupied room. ETC’s Unison Paradigm Occupancy/Vacancy Sensors are a convenient and easy solution for your facility to eliminate that wasted energy, by automatically turning off lighting loads when a room is empty. The low-profile, sleek sensors can be installed anywhere in yourfacility to provide uninterrupted, 24/7/365 operation, without affecting the look and beauty of their surroundings.

APPLICATIONS

  • Classrooms
  • Conference rooms
  • Museums
  • Office spaces
  • Low-use spaces

FEATURES

  • Supports Occupancy or Vacancy detection
  • Passive infrared (PIR) sensing technology
  • Three versions available:
    • Large room
    • Small room
    • High ceiling
  • Walk-thru mode for coverage verification
  • Field-installed coverage masks
  • Supports manual-on/auto-off (default) and auto-on/off modes
  • Software configurable to activate or deactivate any Paradigm system function
  • LinkConnect: two-wire, topology-free bus for power and communication
  • Each sensor counts as one station
  • Available in white and black

GENERAL

  • UL and cUL Listed
  • CE compliant

Specifications

FUNCTIONAL

  • Supports software-configured Auto-On/Auto-Off functionality (occupancy sensing) or Manual On/Auto-Off (vacancy sensing) functions
  • 360° coverage pattern
    • Includes customizable coverage masks
  • No additional power pack required
  • Supports Walk-Thru mode for verifying coverage area
    • Sensor lens illuminates for walk-thru and test mode operation
  • Sensor coverage tested to NEMA WD 7-2000

MECHANICAL

  • Constructed of injection-molded, ABS plastic in Pure White (RAL 9010) or Black (RAL 9004)
  • Electronics assembly and mounting plate included
  • Two cantilevered configuration buttons
  • No visible means of attachment
  • Surface- or backbox-mountable using included mounting plate
    • Supports drywall, plaster, wood and concrete
    • Mounts to any standard electrical box (supplied by other manufacturers)
    • Mounts to compressed-fiber ceilings with included wire form
  • Field-installed lens mask allow customized occupancy detection fields

ELECTRICAL

  • Connect via LinkConnect two-wire control network utilizing low-voltage Class 2 wiring
  • Topology-free and polarity-independent wiring over Belden 8471 or equivalent and one 2.5 mm2 (14 AWG) ESD drain wire
  • Wiring may be bus, loop, homerun or any combination of these

ENVIRONMENTAL

  • Ambient room temperature: 0–40° C (32–104° F)
  • Ambient humidity: Maximum 90% (non-condensing)