ETC P-DOC-W-NR-4

ETC P-DOC-W-NR-4

ETC P-DOC-W-NR-4

ETC P-DOC-W-NR-4

Paradigm Wall-mount Dual Tech Occupancy Sensor-Narrow Angle-Black

SKU: ETC-7184A1412-4
Call for Price

Overview

Buildings waste electricity as a result of lights being left on in an unoccupied room. Occupancy and Vacancy Sensors are a convenient and simple solution for any facility to eliminate wasted energy by automatically turning off lighting loads when a room is empty. The low-profile, sleek sensors can be installed anywhere to provide uninterrupted, 24/7/365 operation, without affecting the look and beauty of their surroundings.

APPLICATIONS

  • Houses of worship
  • Education
  • Hospitality
  • Healthcare facilities
  • Office buildings
  • Conference rooms
  • Meeting rooms
  • Retail

Features

  • Supports for occupancy or vacancy detection as required
    • Mode programmed via commissioning software
  • Passive infrared (PIR) and Acoustic sensing technology
  • Two mounting options available:
    • Ceiling-Mount
    • Wall-Mount
  • Multiple Lensing options available
  • Walk-thru mode for coverage verification
  • Field-installed coverage masks (Ceiling only)
  • LinkConnect: two-wire, topology-free bus for power and communication
  • Ceiling Sensor available in black and white
  • Wall Sensor available in cream, black and white

REGULATORY AND COMPLIANCE

  • UL and cUL LISTED
  • CE marked

Specifications

FUNCTIONAL

  • Supports software-configured Auto-On/Auto-Off functionality (occupancy sensing) or Manual-On/Auto-Off (vacancy sensing) functions
  • Ceiling Sensor:
    • 360-degree coverage pattern
    • Includes configurable coverage masks
    • Small room: 450 sq. ft. at 8’ ceiling, 800 sq. ft. at 12’ ceiling
    • Large room: 1800 sq. ft. at 8’ ceiling, 3000 sq. ft. at 12’ ceiling
    • High ceiling: 300 sq. ft. at 10’ ceiling, 7000 sq. ft. at 40’ ceiling
  • Wall Sensors
    • Wide: 60’ coverage at 7-10’ mounting height. 140 degree field of detection
    • Narrow: 16’ by 75’ coverage pattern at mounting height of 7-10’. 40 degree field of detection
  • Supports walk-thru mode for verifying coverage area
    • Sensor lens illuminates for walk-thru and test mode operation
    • Red illumination for PIR detection
    • Green illumination for Acoustic Detection
  • Sensor coverage tested to NEMA WD 7-2000

MECHANICAL

  • Constructed of injection-molded, ABS plastic in Pure White (RAL9010), Black (RAL 9004) or Cream (RAL 9003 - Wall only)
  • Electronics assembly and mounting accessories included
  • Accessible configuration buttons
  • No visible means of attachment
  • Ceiling Mount:
    • Surface- or box-mountable
    • Supports drywall, plaster, wood and concrete mounting
    • Mounts to standard electrical box (supplied by others)
    • Mounts to compressed fiber ceilings with included wire mounting option
  • Wall Mount:
    • Flush-mount to industry standard backbox, RACO 690 or equivalent

ELECTRICAL

  • Connect via LinkConnect two-wire control network utilizing low-voltage Class 2 wiring
    • Topology-free and polarity-independent wiring over Belden 8471 or equivalent and one #14 ESD drain wire
    • Wiring may be bus, loop, homerun or any combination of these
  • All station terminations utilize removable connectors

ENVIRONMENTAL

  • Ambient room temperature: 0–40° C (32–104° F)
  • Ambient humidity: Maximum 90% non-condensing