ETC P-CCS

ETC P-CCS

ETC P-CCS

ETC P-CCS

Paradigm Central Control Server 1U with Rack Mount Kit

SKU: ETC-7180A1170
Call for Price

Overview

The Paradigm Central Control Server scales up Paradigm systems to master the most complex lighting venues. By integrating a native BACnet communication system and incorporating ETC Virtual and Large-Format Touchscreens, the Paradigm Central Control Server achieves the most comprehensive building-wide control.

APPLICATIONS

  • Hotels
  • Museums
  • Casinos
  • Conference centers
  • Theme parks

FEATURES

  • Designed for use with Unison Paradigm Architectural Control Systems
  • Provides a central interface and control for multiple discrete control systems
  • Supports collection of measured and calculated energy usage
  • Configurable Demand Response integration for load shedding
  • Virtual Touchscreen Stations (VTS) and large-format touchscreen integration
  • Native BACnet IP interface for integration with Building Management Systems (BMS)
  • Supports BACnet event scheduling to ensure lighting events occur on time, even when the BACnet system is offline
  • Provides network time synchronization for all ETC lighting products in the system
  • Provides persistent error logging for the entire lighting control system
  • LightDesigner™ Access: Web browser interface for easy modification, activation and monitoring of your system

REGULATORY AND COMPLIANCE

  • ETL and cETL Listed
  • CE Marked

Specifications

FUNCTIONAL

  • Supports up to 64 Paradigm Architectural Control Processors
  • System
    • Multi-user LiveControl and LiveEdit
    • Network Time Protocol for real-time clock synchronization supporting real and astronomical events
    • Addition of processors to a system proportionately increases the overall capacities
    • Failure of a single Paradigm ACP does not prevent continuous operation of the remaining connected systems
    • Logging of system error messages using Syslog format
    • Support for ANSI / ASHRAE 135.1 BACnet IP protocol with up to 1000 each analog inputs, binary inputs, analog outputs, and binary outputs
  • Diagnostics
    • Event logs are stored in persistent memory using Syslog format
    •  Standard log shall store a history of recent activity
  • Configuration Data
    • Remote upload from a connected PC running Light Designer or another connected Paradigm ACP
    • Stored in persistent memory
    • Remote retrieval from a connected PC running LightDesigner
  • Scalability
    • Supports up to 12 Paradigm ACPs in a single project (pcf)
    • Control Server project (spcf)
    • Supports network time service for synchronization of time and timed events
    • Supports multiple Paradigm projects on the same Ethernet network with logical limits between systems
    • Allows for timed event configuration from an external source using BACnet IP
    • Provides remote use of up to 32 individually customized Virtual Touchscreen application s(VTS)
  • Web User Interface
    • Internal web server accessible via the primary Ethernet port
    • Activate and deactivate presets
    • Schedule global timed events (add/edit/delete)
    • Displays status information and log files
    • Configuration of server settings (date, time, network)
  • California Title 20/24 Compliant

DEMAND RESPONSE

  • Supports external triggering of utility initiated Demand Response
  • Trigger may be RS232, UDP or BACnet
  • Energy reduction may occur by:
    • Zone(s)/ Channel(s)
    • Group(s)
    • Space(s)

ENERGY MANAGEMENT

  • Supports measured energy usage for compatible products using Net3 networking. Contact ETC for compatible products.
  • Supports calculated energy usage of all zones/channels controlled by connected Paradigm Architectural Control Processor(s)
  • Displays energy usage and trends on user interfaces including:
    • 7” Touchscreen (P-TS7)
    • 18” Touchscreen (P-TS18)
    • Touchscreen Interface (P-TSI)
    • Virtual Touchscreen (P-VTS)
    • P-CCS web interface
  • Historical data is stored for up to ten years with data granularity based on the age of the data
  • Energy usage is recorded in 5 minute intervals

MECHANICAL

  • Designed for use in Unison Paradigm Architectural Control Systems
  • Self-contained electronics assembly
  • Enclosure made from 16-gauge formed steel and finished in a black, fine-texture powder coat paint
  • 1U, 19-inch equipment rack mountable
  • Backlit power switch with blue LED status indicator
  • Standard connections for the following interfaces:
    • Front panel USB connection
    • RJ45 Ethernet connection for Lighting Network
    • RJ45 Ethernet connection for Building Lighting Network (BACnet and VTS)
    • Four Rear panel USB connections
    • One RS232 Serial port (diagnostics only)
  • Internal hard drive for storage of configuration data

ELECTRICAL

  • 100-240VAC, 50/60 Hz power input
  • Microprocessor-based technology to provide system wide, multi-project lighting and building controls
  • Two IEEE802.3u-compliant Ethernet connections
    • Primary port for connection to lighting systems for Virtual Touchscreen Interfaces
    • Secondary port for connection to BACnet systems and Virtual Touchscreen Interfaces
  • Automatic restoration to previous power state when returning from power loss
  • System configuration and programming information stored in persistent memory
  • Support of ESTA ANSI E1.17 Advanced Control Networks

THERMAL

  • Ambient room temperature: 0-40°C / 32-104°F
  • Ambient humidity: 5-95% non-condensing