Overview
Mosaic Input/Output Modules expand the advanced show control capabilities of Mosaic allowing interaction with external triggers and systems. Remote I/O modules offer tri-mode inputs or relay outputs and an integrated, bidirectional serial port (RS-232/RS-485) for interfacing to third-party equipment. The module uses simple and reliable Ethernet topology with Power-over-Ethernet (PoE) to connect to supported controllers.
APPLICATIONS
- Integration with third-party products and systems
FEATURES
- Individually configurable tri-mode inputs with support for digital, analog, or contact closure
- Multiple protocol serial port including RS-232/485 serial, or output for 96 DMX channels
- Up to 200 modules supported in a single control system
- Power-over-Ethernet (PoE) powered
- Programmed and configured using Mosaic Designer Software
REGULATORY AND COMPLIANCE
- cETLus Listed
- Conforms to UL-60950-1
- Certified to CAN/CSA-C22.2No.60950-1
- CE Compliant
- California Title 20/24 complian
Specifications
FUNCTIONAL
- MRIO-80-Eight configurable tri-mode inputs configurable for digital, analog, or contact closure
- MRIO-44-Four configurable tri-mode inputs and four relay outputs
- MRIO 08 - Eight fully isolated relay outputs
- RS-232/485 serial output, or up to 96 channels of DMX output
- Tri-modeinputssupport:
- Digital In - Presence of voltage between input and ground. supports active-high and active-low
- Analog In-Uses voltage range as a trigger
- Contact Closure - Uses a voltage-free switch between input and ground
- Relay outputs generate outputs to external systems
- Five-year warranty
MECHANICAL
- Four-unit wide DIN enclosure complies with DIN 43880 and EN60715 (35/7.5rail)
- Rugged aluminum enclosure
- Rotary switch for selecting network address
- All connections use pluggable rising clamp terminals
ELECTRICAL
- RJ45 connection supports 10/100Base-TX Ethernet
- Link and data LEDs
- Static and DHCP addressing support
- PoE powered (IEEE 802.3af, Class 1) 1.5 W typical draw
- Isolated tri-mode inputs are rated for:
- Digital - 24 VDC maximum, internal 2 MOhm pull down
- Analog-0–24VDC range configurable in software
- Contact Closure - Voltage-free with internal 2.2 kOhm pull-up to 5 VDC
- Isolated relay outputs are rated for:
- 1 KV isolation per relay
- 250 mA at 48 V AC/DC
- RS-232 or RS-485 bidirectional serial with support for free syntax ASCII, HEX or Decimal formats
- May be used for DMX output of up to 96 addresses
- Wiring connections made using pluggable 0.2 in (5 mm) rising clamp terminals
THERMAL
- Ambient temperature: 0°C to 50°C (32°F to 122°F)
- 10%–50%relative humidity, non-condensing