ETC ERP48-FT482P

ETC ERP48-FT482P

ETC ERP48-FT482P

ETC ERP48-FT482P

Echo Relay Panel Feedthrough 48-way panel with forty-eight 20 A 208 V double-pole relays

SKU: ETC-7123A1125
MSRP: $14,865.00

Overview

The Echo Relay Panel Feedthrough is a control-oriented switching and power control built with today and tomorrow’s lighting loads in mind. Freely mix normal and emergency 120–347 V single-pole loads and either 120/208 V or 277/480 V double-pole loads in the same enclosure. With built-in station and sensor support via contact input, DMX and Ethernet connectivity, and optional 0–10 V dimming or DALI output, Echo Relay Panels easily integrate into a broad range of systems and applications.

APPLICATIONS

  • Houses of worship
  • Ballrooms and convention centers
  • Multi-purpose rooms
  • Arenas and stadiums
  • Entertainment facilities with DMX control
  • Retrofits for lighting systems with existing breaker panels

Features

  • 120–347 V single-pole and 120/208 V or 277/480 V double-pole switching
  • Up to 48 relays per panel
  • Switches all relays at once or with configurable delay
  • Mechanically latching relays fully rated for 20 A
    • Single-pole relay kits fed by 120 V with 20 A branch breakers are suitable for plug load control
  • Manual ON/OFF override with position indication
  • Relays support field installation and replacement
  • DMX and Ethernet (sACN) control of preset and sequence playback
  • Local user interface provides:
    • Panel configuration
    • Preset and sequence programming and playback
    • Individual channel control
  • Built-in Ethernet port
  • Available 0–10 V, contact input, and DALI control cards
  • UL924 Listed emergency control bypass with load shedding
    • Voltage barrier for normal/emergency mixed use panels

Specifications

REGULATORY AND COMPLIANCE

  • cULus Listed
  • UL508 Listed
  • UL924 Listed
  • Complies with ANSI E1.11 DMX512-A standard
  • Complies with ANSI E1.31 streaming ACN standard

USER INTERFACE

  • Graphical display with LED backlight
  • Button interface with:
    • 0–9 number buttons
    • Up, down, back and enter navigation buttons
    • Test shortcut for local activation of preset, sequence and set level overrides
  • USB interface for upload of setup and software updates

MECHANICAL

  • Panel consists of enclosure, covers with locking doors, and internal subpanels
  • Enclosure constructed of 16-gauge steel finished in black, fine-textured, scratch-resistant powder coat paint
  • Removable conduit panels on top, bottom and sides
  • Full front access with no side clearance required
  • Removable covers for access to Class 1 and Class 2 wiring
  • Locking doors allow controlled access to manual override switch of each relay and Class 2 wiring only
  • All low-voltage wiring is physically separated from AC by a mechanical barrier
  • Removable subpanels containing the electronics and relays can ship separately – contact ETC

ELECTRICAL

  • Discrete feed per circuit supports mixed voltage in a single panel
  • Single panel for up to 48 relays, populated in any combination of single- or double-pole
  • Separate wiring chambers for Class 1 and Class 2 terminations
  • Optional voltage barriers install without tools between relays for separation of normal and emergency circuits

RELAY RATINGS

  • 20 A 347 V General Purpose
  • 20 A 347 V Ballast (HID)
  • 20 A Tungsten
  • Motor Loads:
    • 5 HP @ 120 V
    • 5 HP @ 240/277 V
  • SCCR: 18,000 A @ 277 V (1P); 5,000 A @ 277 V (2P & 480)
  • Inrush: 2000 A (1P only)
  • Isolation: 2,500 V RMS
  • State: Latching
  • Relays are mechanically held
  • Life: 60,000 operations at full load
  • Terminal: Accepts 14–10 AWG copper wire

ENVIRONMENTAL

  • Thermal: 0°C to 40°C (32°F to 104°F) operating temperature
    • 20 A relay - 60 BTU/hr (estimated)
  • Humidity 10%–90%, non-condensing

CONTROL ELECTRONICS

  • Input: 120 or 277 V (+/-15%), 50/60 Hz, ≤ 16 A
  • Multi-tap transformer terminals accept up to 12 AWG wire
  • Control wiring terminations:
    • Control terminals accept maximum of 12 AWG wire
    • Control wiring exiting the panel are Class 2
    • All control terminations utilize removable connectors

FUNCTIONAL

  • Relay modes: Normal (priority/HTP), latch-lock or last-action
  • System-Wide control
    • DMX or sACN input
    • Per-circuit patching
    • Per-circuit threshold
    • 0–200 prioritization
    • Configurable data loss behavior:
    • Play preset; Hold last look; Wait and fade
    • UL 924 emergency lighting with load shedding
  • Application/Space segmented Control
    • Space segmenting: up to 16 spaces per panel
    • Power Sequencing: one 16-step sequence per space
    • Presets: up to 64 per space configurable via local UI
    • Zone control: up to 16 zones per space
  • Monitoring Per Circuit:
    • Breaker-trip notification
    • Relay state
    • Current draw, phase voltage, and energy usage
  • Monitoring Per Space:
    • Active sequences, presets, and clock events
    • Zone levels

ACCESSORIES

  • 0–10 V Dimming Option
    • 24 outputs of 0–10 V sink dimming control rated for 100 mA per output
  • Contact Input Option
    • 24 dry contact inputs which can be used to:
      • Trigger presets and sequences, which will play at the priority configured for architectural sources, or;
      • Directly control one or more outputs. The priority of these outputs is configurable. If nothing is configured, the last action takes precedence
  • DALI Control Option
    • 24 control loops of broadcast DALI control
    • Each loop supports up to 64 ballasts
    • External DALI power supply required
  • RideThru Option
    • Short-term power backup of control electronics
    • Automatically engages when power is lost
    • Recharges during normal power operation
  • Tamper-proof Hardware Kit
    • Special screw heads prevent access to panel interior