ETC ERP 2PR

ETC ERP 2PR

ETC ERP 2PR

ETC ERP 2PR

Echo Relay Panel 2-Pole Relay Kit

SKU: ETC-7123K1011
MSRP: $165.00

Overview

The Unison Echo Relay Panel is a control-oriented power center built with today and tomorrow’s lighting loads in mind. It supports up to 24 relays with integral branch breakers, power-usage reporting and sophisticated control inputs. With built-in station and sensor support via contact input, DMX and Ethernet connectivity, and optional 0–10 V dimming or DALI output, Echo Relay Panels easily integrate into a broad range of systems and applications.

APPLICATIONS 

  • Theaters
  • Schools
  • Houses of worship
  • Conference centers
  • Retail shops and restaurants

FEATURES

  • Main Feed relay panel with support for 277/480 V or 240/415 V three-phase four-wire plus ground
  • 24-position relay panel with support for 1-pole relays
  • 30-position breaker subpanel with support for 1-pole breakers
  • DMX and Ethernet (sACN) control of preset and sequence playback
  • Local user interface provides:
    • Panel configuration
    • Preset and sequence programming and playback
    • Individual channel control
  • Built-in Ethernet port
  • Available 0–10 V, contact input, and DALI control cards
  • UL 924 Listed emergency control bypass with load shedding

Specifications

REGULATORY AND COMPLIANCE 

  • cULus Listed
  • UL 508 Listed
  • UL 924 Listed
  • Complies with ANSI E1.11 DMX512-A standard
  • Complies with ANSI E1.31 streaming ACN standard

USER INTERFACE 

  • Graphical display with LED backlight
  • Button interface with:
    • 0–9 number buttons
    • Up, down, back and enter navigation buttons
    • “Light bulb” test button for local activation of preset,
  • sequence and set level overrides
  • USB interface for upload of setup and software updates

MECHANICAL

  • Enclosure constructed of 16-gauge steel finished in black,fine-textured, scratch-resistant powder coat pain
  • Door options available for surface- or recess-mount applications.
    • Flush-mount door extends 1 inch beyond all panel edges to
  • hide wall cutout
  • Removable outer panel includes integral locking door to limit access to electronics, breakers and local relay overrides
  • Full front access with no side clearance required
  • Removable covers for access to Class 1 and Class 2 wiring

ELECTRICAL

  • Main feed power input supports 277/480 V or 240/415 V
  • Separate wiring chambers for Class 1 and Class 2 terminations
  • Max input current: 200 A
  • Main circuit breaker support: 150 A and 200 A
  • Short circuit rating: 14,000–65,000 A symmetrical (See chart at right)
  • 20 A branch circuit breakers standard; 80% rated
  • Inrush-pulse tolerance: 8–10.5 times rated current for halfcycle at 60 Hz

ENVIRONMENTAL

  • Thermal: 0°C to 40°C (32°F to 104°F) operating temperature
    • Relays (all) - 39.28 BTU/hr
  • Humidity: 5%–95%, non-condensing

RELAY RATINGS

  • 20 A Ballast (HID)
  • 16 A Electronic Ballast
  • 20 A Tungsten
  • 14 A Motor Load
  • Isolation: 4000 V RMS
  • State: Latching; mechanically held
  • Life:
    • 100,000 cycles at full resistive load
    • 30,000 cycles motor, inductive, or tungsten
  • Current-reporting accuracy: +/- 5% of connected load

CONTROL ELECTRONICS

  • Input: 120–277 V (+/-15%), 50/60 Hz, <16 A
  • Multi-tap transformer terminals accept up to 12 AWG wire
  • Control wiring terminations:
    • Control terminals accept maximum of 12 AWG wire
    • Control wiring exiting the panel are Class 2
    • All control terminations utilize removable connectors

FUNCTIONAL

  • System-Wide control
    • DMX or sACN input
      • Per-circuit patching
      • Per-circuit threshold
      • 0-200 prioritization
    • Configurable data loss behavior:
      • Play preset; Hold last look; Wait and fade
    • UL 924 emergency lighting with load shedding
  • Application/Space segmented Control
    • Space segmenting: up to 16 spaces per panel
    • Power Sequencing: one 16-step sequence per space
    • Presets: up to 64 per space configurable via local UI
      • Zone control: up to 16 zones per space
    • Monitoring Per Circuit:
      • Breaker-trip notification
      • Relay state
      • Current draw, phase voltage, and energy usage
    • Monitoring Per Space:
      • Active sequences, presets, and clock events
      • Zone levels

ACCESSORIES

  • 0–10 Dimming Option
    • 24 outputs of 0–10 V sink dimming control rated for 100 mA per output
  • Contact Input Option
    • 24 dry conta ct inputs for direct control of relays
  • DALI Control Option
    • 24 control loops of broadcast DALI control
    • Each loop supports up to 64 ballasts
    • External DALI power supply required
  • RideThru Option
    • Short-term power backup of control electronics
    • Automatically engages when power is lost
    • Recharges during normal power operation
  • Tamper-proof Hardware Kit
    • Special screw heads prevent access to panel interior