Overview
Buildings waste electricity as a result of lights being left on in an unoccupied room. Occupancy and Vacancy Sensors are a convenient and simple solution for any facility to eliminate wasted energy by automatically turning off lighting loads when a room is empty. The low-profile, sleek sensors can be installed anywhere to provide uninterrupted, 24/7/365 operation, without affecting the look and beauty of their surroundings.
Applications
- Houses of worship
- Education
- Hospitality
- Healthcare facilities
- Office buildings
- Conference rooms
- Meeting rooms
- Retail
Features
- Manual-on/auto-off (Vacancy Sensor) and auto-on/off (Occupancy Sensor) versions
- Multi Space Preset functionality
- Passive infrared (PIR) and Acoustic sensing technology
- Two mounting options available:
- Ceiling-Mount
- Wall-Mount
- Multiple Lensing options available
- Walk-thru mode for coverage verification
- Field-installed coverage masks (Ceiling only)
- EchoConnect: two-wire, topology-free bus for power and communication
- Ceiling Sensor available in black and white
- Wall Sensor version available in cream, black and white
REGULATORY AND COMPLIANCE
- cULus Listed
- CE compliant
Specifications
FUNCTIONAL
- Occupancy sensors support configurable auto-on/auto-off functionality (occupancy sensing) functions
- Vacancy sensors support configurable manual-on/auto-off (vacancy sensing) functions
- Ceiling Sensor:
- 360-degree coverage pattern
- Includes configurable coverage masks
- Small room: 450 sq. ft. at 8’ ceiling, 800 sq. ft. at 12’ ceiling
- Large room: 1800 sq. ft. at 8’ ceiling, 3000 sq. ft. at 12’ ceiling
- High ceiling: 300 sq. ft. at 10’ ceiling, 7000 sq. ft. at 40’ ceiling
- Wall Sensors
- Wide: 60’ coverage at 7–10’ mounting height. 140 degree field of detection
- Narrow: 16’ x 75’ coverage pattern at mounting height of 7–10’. 40 degree field of detection
- Supports walk-thru mode for verifying coverage area
- Sensor lens illuminates for walk-thru and test mode
- Red illumination for PIR detection
- Green illumination for Acoustic detection
- Sensor coverage tested to NEMA WD 7-2000
MECHANICAL
- Constructed of injection-molded, ABS plastic in Pure White (RAL9010) or Black (RAL 9004) or Cream (RAL 9003 – Wall only)
- Electronics assembly and mounting accessories included
- Accessible configuration buttons
- No visible means of attachment
- Ceiling Mount:
- Surface- or box-mountable
- Supports drywall, plaster, wood and concrete mounting
- Mounts to standard electrical box (supplied by others)
- Mounts to compressed fiber ceilings with included wire mounting option
- Wall Mount:
- Flush-mount to industry standard backbox, RACO 690 or equivalent
ELECTRICAL
- Connect via EchoConnect two-wire control network utilizing low-voltage Class 2 wiring
- Topology-free and polarity-independent wiring over Belden 8471 or equivalent and one #14 ESD drain wire
- Wiring may be bus, loop, home run or any combination of these
- Up to 500 m (1,640 ft) of control wiring per system
- Supports optional Cat5/5e wiring using Belden 1583A or equivalent
- Requires optional Cat5 termination accessories
ENVIRONMENTAL
- Ambient room temperature: 0°–40° C (32°–104° F)
- Ambient humidity: Maximum 90% non-condensing
BASIC MODE FUNCTIONALITY
- Occupancy Sensors
- Occupancy Event: Play selected default preset
- Vacancy Event: Space off
- Vacancy Sensor:
- Occupancy Event: N/A
- Vacancy Event: Space off
CUSTOM MODE FUNCTIONALITY
(Requires Programing With EchoAccess® Mobile App and additional connection hardware)
- Occupancy Events Supported
- Preset Activate*
- Zone Set to Level
- Space Set to Level
- Vacancy Events Supported
- Preset Activate*
- Zone Set to Level
- Space Set to Level
- Space Off*