Overview
ETC’s Unison DRd Series Rack Enclosures are the workhorses behind the scenes, supporting two processor options and a variety of dimming, switching and option modules. DRd Rack Enclosures are trusted for their reliability and versatility
Applications
- Houses of worship
- Hotels
- Convention centers
- Theatres
- Schools
- Restaurants
Features
- All-On – clearly marked switch allows for all loads to be turned on to full, without the need for a control processor
- HighFault – protection from power spikes and surges with short-circuit current ratings from 22,000 amps
- Regulation – monitoring and adjustment of incoming line voltage with min and max scale voltages
- Bypass – emergency lighting control bypass input with load shedding
- Hold Last Look – dimming engine holds the last output during any loss of control
- QuickBoot – dimming engine boot time of less than four seconds
- HiRes Dimming – support for 16-bit DMX and over 65,000 steps of dimming
Specifications
GENERAL
- DRd rack enclosures available in two sizes: DRd6 with support for six modules and up to 12 circuits and DRd12 with support for 12 modules and up to 24 circuits
- Full eight-year warranty
- FUNCTIONAL
- High-density dimming for incandescent, fluorescent, neon, cold cathode, electronic and magnetic low-voltage transformer load types
- 16-bit DMX input
- Designed for reliable, continuous operation
MECHANICAL
- Welded 18-gauge formed steel construction
- Surface- or floor-stand mount
- Hinged, lockable full-height door with electrostatic air filter
- Fine-textured, scratch-resistant epoxy paint
- Integral low-voltage fan
- Modular control electronics
ELECTRICAL
- UL Models
- 120/208 V Three Phase, Four Wire + Ground
- Supports Voltages down to 100/170 V Nominal
- 120/240 V Bi-Phase, Three Wire + Ground supported using reconfigurable bus bars
- 277/480 V Three Phase, Four Wire + Ground
- Supports Voltages down to 240/415 V Nominal
- Voltage tolerance ± 10%
- Single-Pole, Neutral Disconnect or Residual Current Device (RCD) per dimmer
- Operating frequency: 50–60 Hz
- DRd6/DRd12 Rack Enclosure fault current protection:
- 22,000 A Short Circuit Current Withstand
- 120/208 V Three Phase, Four Wire + Ground
THERMAL
- Ambient room temperature: 0°C to 40°C (32°F to 104°F)
- Ambient humidity: 10%–90%, non-condensing
REGULATORY AND COMPLIANCE
- All enclosures are cULus Listed
- UL 924 Listed
ACCESSORIES AND OPTIONS
CONTROL PROCESSORS
- Echo Architectural Control Processor (E-ACP)
- Paradigm Architectural Control Processor (P-ACP)
STATION POWER OPTIONS
- Echo Station Power Module (E-SPM)
- Provides EchoConnect power for up to 16 Echo control devices and 16 Echo output devices
- Supports up to 500 m (1,640 ft) of station bus wiring
- Paradigm Station Power Module (P-SPM)
- Provides LinkConnect power for up to 32 Unison stations
- Provides 24 V auxiliary power for interface and touchscreen stations
- Allows for up to 500 m (1,640 ft) of station bus wiring
ACCESSORIES
- Unison RideThru Option (URTO)
- Short-term power backup of control electronics for at least 10 seconds
- Automatically engages when power is lost
- Recharges during normal power operation
- Unison Battery Pack Option (UBPO)
- Long-term power backup of control electronics for at least 90 minutes
- Automatically engages when power is lost
- Recharges during normal power operation
- 0–10 V (four-wire) control option (DRd-LVD)*
- 0–10 V (sink) driver and ballast control
- Up to 24 outputs
- 100 mA per channel
- DALI Ballast option (DRd-DALI)*
- Support for 24 loops of DALI control in broadcast mode
- Up to 64 ballasts per output
- External DALI power supply required (by others)