Overview
The Pro Four-Cell Linear provides medium- to long-throwLED illumination for locations where hanging space is limited.Manufactured from high-grade, powder-coated aluminum andsteel, the luminaire is equipped with a yoke for maximum focusingflexibility. The Pro Four-Cell Linear is entirely convection cooled,resulting in zero noise emission.
The Pro Four-Cell Linear connects directly to a mains supply andincludes an onboard power supply. Intensity is controlled directlyusing a wired-DMX connection to the luminaire’s RJ45/Etherconconnectors.
ArcSystem has been specifically developed for auditorium lightingapplications where high-quality, extremely accurate and smoothdimming is required. The use of onboard device management in thedriver allows all luminaires to be addressed remotely, ensuring fastand simple installation.
APPLICATIONS
- Auditoriums
- Work lights
- Lobbies
- Houses of worship
- Museums
- Studios
FEATURES
- Wired-DMX and RDM control protocols
- Stepless, smooth dimming to absolute zero
- Convection cooled
- Silent operation
- Black or white paint finish options
- Custom color paint finishes available by special order
- Available as a dual-input emergency version
Specifications
Source
- LED details: Bridgelux Vero 13 (standard) Vesta 15 (FTW)
- Max field lumens: 8,445 (3000 K 50°)
- Max total lumens: 9,152 (3000 K 50°)
- Lumens per watt: 91
- L70 rating (hours to 70% output): 50,000 hours
Color
- Colors used: Fixed white
- Color temperature options: 2700 K, 3000 K, 3500 K, 4000 K, 5000 K
- Fade to warm: Optional on 2700 K and 3000 K
Optical
- Beam angle range: 19 / 24 / 37 / 60
- CRI: >90
- TM-30-18 data: Refer to ArcSystem photometry guide
- Photometry data: See below of refer to ArcSystem photometry guide
Control
- Input method: DMX-512 via RJ45/etherCON connector
- Protocols: DMX, RDM
- Modes (footprint): 1-channel / 4-channel
- RDM configuration: Yes (with RDM option)
- UI type: No Local UI
- Local control: No
Electrical
- Voltage range: 100–240 VAC IEC or 100–277 VAC hard-wired
- Input method
- Standard luminaire options:
- Option 1: IEC Connector
- Option 2: wiring compartment with one half-inch knock-outs for field wiring
- Emergency luminaire: Wiring compartment with two half-inch knock-outs for field wiring
- Inrush: 65 A at 120 V (first half-cycle)
- Wattage (max /standby): 100 W / <3 W
- Current draw: 0.84 A at 120 V
- Power factor: >0.9
Thermal
- Ambient operating temp: 0°–40° C (32°–104° F)
- Fan (controllable): N/A (convection cooled)
- BTUs/hour: 341
Physical
- Materials: Die-cast aluminum and cold-rolled steel
- Color options: Black, white or custom color
- Mounting options: Yoke
- IP rating: IP-20 (dry locations only)
- Weight: 5.99 kg (13.20 lb)
Emergency connection
A dual-input emergency version of this luminaire is available. Emergency luminaires require two line-voltage inputs that perform the following functions:
- Normal power/emergency power
- Normal power sense input
The sense input is used to detect whether normal utility power has been lost. This will force the luminaire on at 100% intensity running fromthe maintained supply. There is no control of the luminaire via wired-DMX until normal utility power is restored to the sense input.